Configuring the DPRI 2922 Via the NCM 2000 Craft Interface
3-26 Verilink DPRI 2922
Diagnostics Menu
The
Diagnostics Menu
is used to troubleshoot the network and
data ports. From the
Main Menu
, Figure 3-1, enter
D
to access the
Diagnostics Menu
, Figure 3-18.
Figure 3-18 Diagnostics Menu
Table 3-16
Diagnostics Menu Commands
T1 Port
Diagnostics
Menu
For diagnostics on the T1 port, enter
P
from the
Diagnostics Menu
,
Figure 3-18, to access the
T1 Port Diagnostics Menu
. This menu
activates or deactivates loopbacks, and sends test patterns from
the network port.
NOTE: If the loopback does not activate, use the T1 Port Configuration
menu to verify that the port is in service.
Figure 3-19 T1 Port Diagnostics Menu
Command Description
P E1/T1 port—This option displays the T1 Port Diagnostics Menu, Figure 3-19, Table 3-17
D Data port—This option displays the Data Port Diagnostics Menu, Figure 3-20, Table .
X Exit this Screen—Returns you to the NCM Main Menu, Figure 3-1, Table 3-2.
[0.0.0.5] [1,2] DPRI 2922 > d
-- DPRI 2922 DIAGNOSTICS MENU --
P) E1/T1 Port D) Data Port
X) exit this screen
[0.0.0.5] [1,2] DPRI 2922 >
-- DPRI 2922 T1 PORT DIAGNOSTICS MENU --
PORT 1 PORT 2
Loop type NONE NONE
Test Pattern NONE NONE
Test Error Counter 0 0
Ln) Line Loop Pn) Payload Loop
Rn) Local Loop Tn) Test Pattern
An) Send LLB BOP Bn) Send PLB BOP
En) Reset Test Counter X) exit this screen
[0.0.0.5] [1,2] DPRI 2922 >