Verilink PRISM 3301 (34-00239.5) Product Manual Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Computerhardware Verilink PRISM 3301 (34-00239.5) Product Manual herunter. Verilink PRISM 3301 (34-00239.5) Product Manual User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Intelligent T3

iPRISM 3301Intelligent T3CSU/DSUAugust 199934-00239.5

Seite 2 - Acknowledgment

2 CHAPTER 1: GENERALSpecificationsNetwork InterfaceLine Rate: 44.736 Mbps (± 20 ppm) Line Framing: C-Bit Parity FramingLine Code: B3ZS (Bipolar with

Seite 3 - Customer Service

Specifications 3EnvironmentalOperating Temp: 32° to 122°F (0° to 50°C)Humidity: 10% to 90% (non-condensing)CompatibilityAT&T TR 54014: May 1

Seite 4 - Safety Precautions

4 CHAPTER 1: GENERAL

Seite 5 - Table of Contents

2INSTALLATIONThis chapter contains information and instructions required to install the PRISM 3301. Included are initial inspection procedures, mounti

Seite 6 - Optional Equipment

6 CHAPTER 2: INSTALLATIONRack MountingThe PRISM 3301 is housed in a metal case intended for desktop installation. The rack-mount hardware included in

Seite 7 - Where to go for

Front Panel Port Connections 7Front Panel Port ConnectionsThe PRISM 3301 contains a local access port and two BNC access jacks on the front pane

Seite 8 - Conventions

8 CHAPTER 2: INSTALLATIONFCC rules require interconnecting cables carrying high-speed data be shielded appropriately minimizing radio frequency inter

Seite 9 - Features

Rear Panel Port Connections 9This port supports only the Receive Data, Transmit Data, Data Terminal Ready, and Data Carrier Detect leads. Contro

Seite 10 - Specifications

10 CHAPTER 2: INSTALLATIONAC PowerThe PRISM 3301 requires a 110-volt AC power supply. The rear panel power receptacle is an industry standard male re

Seite 11

3FRONT PANEL INTERFACEThe PRISM 3301 front panel contains twelve LEDs indicating unit status. The alarm messages associated with these indicators, inc

Seite 12 - 4 CHAPTER 1: GENERAL

iiCopyright NoticeCopyright © 1999 Verilink Corporation. All rights reserved.This document does not create any express or implied warranty about Veril

Seite 13 - NSTALLATION

12 CHAPTER 3: FRONT PANEL INTERFACEBPVA BPV error (also known as a Line Code Violation) is two consecutive pulses of the same polarity. The event is

Seite 14 - Rack Mounting

RX AIS 13Table 3-1 DTE and Network Alarm Conditions and ResponsesAlarm Type LED Signal(s) Description Operator ResponseLoss of DTE Clock TxAI

Seite 15 - Rear Panel Port

14 CHAPTER 3: FRONT PANEL INTERFACE

Seite 16 - 8 CHAPTER 2: INSTALLATION

4TERMINAL INTERFACEThe PRISM 3301 can be managed using an ASCII terminal or a personal computer running terminal emulation software or SNMP. The PRISM

Seite 17 - Data Carrier Detect leads

16 CHAPTER 4: TERMINAL INTERFACEIf a password has been previously established, enter the correct password to continue the session. The password is ca

Seite 18 - 10 CHAPTER 2: INSTALLATION

Configuration Commands 17SET NET AIS TX-XBITThis command sets the AIS TX-Xbit option. The choices are 0 and 1. SET DTE RATEThis command configu

Seite 19 - NTERFACE

18 CHAPTER 4: TERMINAL INTERFACESET SUPERVISORY DIAL-STRINGThis command establishes the AT command dial string.SET SUPERVISORY HANGUP-STRINGThis comm

Seite 20

Configuration Commands 19SET SNMP TRAPOption of 1-6. After selecting the option, enter the IP address.SET SNMP SYSTEMThis command establishes t

Seite 21 - 13

20 CHAPTER 4: TERMINAL INTERFACESET ADMINISTRATION CIRCUITThis command sets the circuit number (up to 24 alphanumeric characters) used for network ma

Seite 22

Configuration Commands 21SET DATALINK TERMINAL DTEThis command initializes the terminal type for the near-end unit as DTE.SET DATALINK TERMINAL

Seite 23

iiiFCC RequirementsChanges or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authorit

Seite 24 - Commands

22 CHAPTER 4: TERMINAL INTERFACELocation ID Code. Transmitted in all three FDL messages.Frame ID Code. Transmitted in all three FDL messages.Unit.

Seite 25 - Configuration Commands

Configuration Commands 23QUERY ALARMSThis command retrieves an entire alarm/event queue of related information. The list displays one screen at

Seite 26 - HAPTER 4: TERMINAL INTERFACE

24 CHAPTER 4: TERMINAL INTERFACEUser Tx Remote Line Loop-down Code to FEHSSI Tx Remote Line Loop-up Code to FEHSSI Tx Remote Line Loop-down Code to F

Seite 27 - {password}

Configuration Commands 25QUERY PERFORMANCE SFEThis command displays the performance data for Short Failure Event. A Short Failure Event (SFE) i

Seite 28

26 CHAPTER 4: TERMINAL INTERFACETest CommandsThe TEST commands perform loop and system tests on the unit. The PRISM 3301 provides three loopback opti

Seite 29

Configuration Commands 27TEST LOOP REMOTE CLEARThis command clears the remote loopback test.TEST LOOP REMOTE REQUESTThis command sends a patter

Seite 30

28 CHAPTER 4: TERMINAL INTERFACEREBOOT COLDThis comand resets the system configuration to the factory default values. All user-defined values are era

Seite 31

AMIB REFERENCEThis unit has an embedded SNMP agent which can be accessed through the built-in SLIP interface. Through this interface, access is gained

Seite 32

30 APPENDIX A: MIB REFERENCERFC 1407 MIBRFC 1407 is used to manage DS3/E3 interfaces, and in this case, a T3 interface. The following lists the objec

Seite 33 - Example B

RFC 1407 MIB 31dsx3SendCode dsx3ConfigEntry 7 read-write This variable indicates what type of code is being sent across the DS3/E3 interface by

Seite 34 - Local Line Loopback

iv•Technical Training on network concepts and Verilink products at (800) 837-4546, ext. 346 and [email protected]•Web site at www.verilink.com•FAX

Seite 35 - Local 3301

32 APPENDIX A: MIB REFERENCEdsx3FarEndConfig{ 1.3.6.1.2.1.10.18.9 } The DS3 Far End Configuration Table contains configuration information reported

Seite 36 - REBOOT WARM

RFC 1407 MIB 33dsx3FracTable{1.3.6.1.2.1.10.18.13} Implementation of this group is optional. It is designed for those systems dividing a DS3/

Seite 37 - EFERENCE

34 APPENDIX A: MIB REFERENCEPRISM3301 MIB{ 1.3.6.1.4.1.425.2.8.1 } The PRISM 3301 proprietary MIB contains the Network, DTE, Current (current TR 540

Seite 38 - RFC 1407 MIB

PRISM 3301 MIB 35t3DatalinkConfig{ 1.3.6.1.4.1.425.2.8.1.2 } This table defines the PRISM 3301 Datalink Configuration, Status, and Control Ob

Seite 39 - Object Name Object ID

36 APPENDIX A: MIB REFERENCEt3CurrentConfig{ 1.3.6.1.4.1.425.2.8.1.4 } This table defines the PRISM 3301 (TR 54014) Performance Monitoring table.t3

Seite 40 - PPENDIX A: MIB REFERENCE

PRISM 3301 MIB 37t3TotalConfig{ 1.3.6.1.4.1.425.2.8.1.6 } The Total table contains the cumulative sum of the various performance parameters f

Seite 41

38 APPENDIX A: MIB REFERENCETXPORT MIB{ 1.3.6.1.4.1.425 } The TXPORT MIB includes information bases supported by Verilink products.companyInfo{ 1.3

Seite 42 - 3301 MIB

Definition of Traps 39Definition of TrapsVerilink products with SNMP support provide for detecting and reporting network alarms. When an alarm

Seite 43 - PRISM 3301 MIB

40 APPENDIX A: MIB REFERENCEEnterprise Specific Traps{ 1.3.6.1.4.1.425.4 } These traps apply to the PRISM 3301.Trap ID Trap Title Description900 Sy

Seite 44

B ORDERING INFORMATION AND OPTIONAL EQUIPMENTOrdering InformationThe PRISM 3301 unit is available in only one configuration with the default part num

Seite 45

vTable of ContentsFront MatterCopyright Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iiTrademarks . . . . . . . . . . . .

Seite 46 - TXPORT MIB

42 APPENDIX B: ORDERING INFORMATION AND OPTIONAL EQUIPMENT

Seite 47 - Definition of

viSET PROGRAM EPROM . . . . . . . . . . . . . . . . .19SET ADMINISTRATION PASSWORD {password} NAME {name} LEVEL {1,2,3} . .19SET ADMINISTRATION PASSW

Seite 48 - Specific Traps

ABOUT THIS GUIDEWhat is a Reference Manual?This is a reference manual. It provides information about unit installation, configuration, testing, and tr

Seite 49 - QUIPMENT

viii ABOUT THIS GUIDEConventionsThe following table lists the conventions used throughout this manual.Convention DescriptionNotices call attention to

Seite 50

1GENERALIntroductionThe PRISM 3301 is an intelligent, SNMP-managed T3 Data and Channel Service Unit. It provides a standard High-Speed Serial Interfac

Kommentare zu diesen Handbüchern

Keine Kommentare