C100 and C150 Specifications
A-2
Verilink C100 and C150 T1/FT1 CSU/DSU
6/15/99
Interfaces—Electrical (DSX-1 Channel)
(C150 only) Bipolar AMI/B8ZS
Mechanical—Sync Channel
RS530, RS422, RS232; 25 Pin female V.35; 34 Pin female
Mechanical—DSX-1 Channel (C150 only)
Bipolar: 8-position RJ48C
Format, Sync channel Binary Serial Synchronous
Format, DSX-1 channel (C150 only) Bipolar AMI
LDM Mode Will drive up to 6000 feet when used as
LDM (Limited Distance Modem).
Network protection
Pulse Insertion Pulse Insertion will occur when the CI
inputs more than 15 consecutive ZEROS o
when the CI does not input at least “n”
ONES in each and every time window of 8 X
(n+1) bits (where “n” = 1 to 23).
Certification Meets FCC Part 15 and Part 68 Complies
with AT&T Tech Pub 62411, 54016 and ANSI
T1.403-1989
Programming Programmed by 7 DIP switch packs or
ASCII CRT
Console Port Compatible with VT100 CRTs. RS232
interface with speed of 9600 bps with 8 data
bits, 1 stop bit and no parity. Supports dial-
in modems. Control-D used for disconnect.
Indicators
CI Chan TX DATA Lit when CI RX DATA is spacing.
CI Chan RX DATA Lit when CI TX DATA is spacing.
CI CCI Chan RTS Lit when CI RTS is spacing.
CI Chan CTS Lit when CI CTS is spacing.
CI Chan DSR Lit when CI DSR is spacing.
CI Chan Carrier Lit when Carrier to Channel is on.
CI Chan DTR Lit when CI DTR is spacing.