Interpreting the LED indicators
Red Zone Encryption Management System (REMS) User Manual
6-9
Flashing Red
Bipolar Violation or CRC-6 indicator.
Flashing Red and Yellow
CSU is looped toward the network and errors
are being received (BPV or CRC-6).
Not Lit
NCC is not powered up, power loss, or self test
failure.
REMS master FBR
NCC 2020 front
panel LEDs
There are two NCC 2020 modules in each REMS, one in the FBR and
one in the BRC. The NCC 2020 module LEDs referred to in this
subsection are those of the master FBR (set to 64).
Figure 6-3 FBR NCC 2020 Front Panel Showing LED Indicators
Decoded FBR NCC 2020 LED indicators
EQPT DTE input from terminal equipment.
NET Signal information from BRC RCV signal in
Black Zone.
STAT (on BRC) Each Green flash indicates a message received
from the Black Zone. (LEDs on the FBR
actually flash twice very quickly, the first flash
is the “decrypted” unencrypted PRM, the
second flash is the BRC message, which
contains the intelligible PRM.)
REV <x>
MON
NET
NET
OUT
CRAFT
NET
STAT
EQPT
FUNCTION
EXE
IN
NCC
00
2020
LED Indicators:
EQPT
OUTIN EQPT
• Equipment
• Networ
• CSU Status
Seitenansicht 68