Configuring the T1 Network
5-76
Access Manager 2000 User Manual
Figure 5-14 Typical
NCC or TAC configuration option menu
These options are described in the following sections.
This option determines whether the circuit element is installed and
operational. This option, marked with an asterisk (*), must be set to YES
in order to enable any of the following options, including collection of
performance monitoring data, alarm reporting, etc.
You must set the Installed and Operational option for the
circuit element’s parent node to YES before Access Manager will allow
you to set this option to YES for the circuit element. The default setting
is NO.
These options enable or disable an NCC, CCC, or TAC collection of near-
end or far-end performance data.
If you select YES for either option, also press and then select the
network and/or EQP data registers to be retrieved. The register types are
NET User, NET Additional, and EQP.
The near-end defaults are NET User=YES, NET Additional=NO,
and EQP=NO. All far-end defaults are NO.
Installed and
Operational
Retrieve Near-En
Performance Data /
Retrieve Far-En
Data